Posts

Biomass Boiler Sangüesa

Overview Boiler Data Boiler Design: vertical 3-pass boiler with external EcoSteam Flow: 115 t/h  at 530°C / 80 barBoiler Width: 9 mFuel: Biomass-cereal straw 100%SPG in Operation since: June 2019 / 2x Type EG10XLShock Pulse Interval: 1 SP/h Improvement of the Cleaning Process The availability of the plant has considerably… Read More

MSWI KEZO Hinwil

Overview 24 t/h steam capacity per boiler3rd pass: W 5 x L 1.8 m x H 10 mbundles: Pitch H/V/tube Da x t; bundle height PSH2: 130 / av. 80 / 38 x 5 mm; ca. 0.9 m FSH1: 140 / av. 80 / 38 x 5 mm; 0.9 m… Read More

MSW Boiler Lucerne (Perlen)

Overview 2 boilers with 58 t/h steam flow per unit, since 2015.Capacity increase to 70 t/h in 2020 (120% of the original design)Boiler width 5.5 m6x Shock Pulse Generator EG10L, since 01/2015 (3 per boiler), enable to maintain a constant RG temperature at the inlet to the horizontal pass, even… Read More

MSW Boiler Zurich

Overview 52 t/h steam flow, 40 bar, 420°CBoiler width 7.2 mThe 3rd pass contains a separation wall in the middle of the pass1 x Shock Pulse Generator TwinL, since 30.11.2015; at 2nd passGood cleaning effect at 2nd an 3rd pass, significantly lower flue gas temperature at inlet to horizontal pass;… Read More

Biomass Boiler Silbitz

Overview 28 t/h steam capacity, 46 bar, 425°C4 pass vertical boilerBoiler width: 3.9m; 3rd pass: W3.9xL2.2mBundle height: 0.7 / 1.9 / 1.9 / 1 m4 x EG10, since 10/2011 (1st pass; 2nd pass;3rd pass: below SH1; 4th pass: middle of pass)Very positive cleaning effect in 1st pass: large build up… Read More

EfW plant Kotka

Overview Energy from Waste Plant, incinerating municipal solid waste4-pass horizontal boiler39 t/h steam capacity2nd pass: W 4.9 x L 2.7 x H 13m 3rd pass: W 4.9 x L 3.3 x H 13m2 x Shock Pulse Generators EG10 (SPG), installed since 01/2010, located in 2nd + 3rd passSince installation of… Read More

Industrial Boiler Aomori

Overview Energy from Waste Plant, incinerating 120’000 t/y shredding residues, sewage sludge and medical wasteShredding residues originate from recycling of cars, trains, industrial wastes, household appliances, etcThe plant consists of a fluidized bed gasifier, an ash melting furnace and a boilerMetals (Fe, Al, Cu), vitrified glass and fly ash are… Read More

MSW Boiler NL-Twence

Overview 62 t/h steam flow, 43 bar, 414°C4-pass horizontal boiler; width empty pass: 7.6m; width convection pass: 6.0mbundles: Pitch T/L/tube Diameter; bundle height EVAP1: 120 / 120 / 44.5; 6.3m SH3: 120 / 120 / 44.5; 6.3m SH2: 120 / 120 / 44.5; 6.3m SH1: 120 / 120 / 44.5;… Read More

×